Engineering and design

Purlin design.

Z, C and Sigma purlins designed with diaphragm action (sheeting), to improve the stiffness of roofs and façades.

Diaphragm action

Less steel, more stiffness.

We select the optimum section, calculate wind, snow, permanent and accidental loads, and check to EN 1993-1-3 and CTE DB-SE-A.

Including diaphragm action makes it possible to optimise sections and reduce the steel required.

Roof purlins of a steel structure

Why Jansa Metal

Common-sense engineering.

Sheeting effect

Built into the design of Z, C and Sigma purlins.

All sections

We choose the most suitable one for each geometry and load.

Site reality

We take into account available sections, erection and other trades.

Technical rigour

Drawings, calculation notes and verifiable recommendations.

How we do it

Four steps.

1. Technical study

Structural type, geometry, loads and project requirements.

2. Section selection

Lapped Z purlin, or C or Sigma depending on the spans.

3. Calculation

Including the effect of the cladding, to EN 1993-1-3.

4. Report

Drawings, calculation notes and construction recommendations.

In detail

Which purlin for each case.

Z purlin

The most widely used for long-span roofs: it can overlap at the intermediate support, which ensures structural continuity.

C purlin

Better suited to façades and simple spans.

Sigma purlin (Σ)

High stiffness for its weight, for long spans with heavy loads and areas of high wind.

FAQ

What we are asked most.

What are purlins?

Secondary members between frames that support the roof or façade and transfer its loads.

What is diaphragm action?

The contribution of the roof panel to overall stiffness when it is properly fixed to the purlins.

What is the difference between Z, C and Sigma?

Z sections can be lapped over long spans, C sections work well on façades and simple spans, and Sigma sections give high stiffness for their weight.

Which roofs do you design for?

Mono-pitch and duo-pitch, flat, curved and low-pitch roofs, on industrial, logistics, commercial and agricultural buildings.

Which standards do you apply?

EN 1993-1-3 for cold-formed profiles, EN 1991-1-3 for snow and EN 1991-1-4 for wind, with the national annexes.

Which loads are considered?

Permanent and imposed loads, wind, snow and lateral buckling effects.

Do you also design edge, ridge and eaves purlins?

Yes, and special cases with valleys or roof penetrations.

Get your purlins designed.

Send us the geometry and the expected loads.